Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 8.726
1.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722126

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Delayed Diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve , Pulmonary Artery , Thrombosis , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Echocardiography, Transesophageal/methods , Thrombosis/diagnostic imaging , Thrombosis/etiology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Female , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/surgery , Pulmonary Embolism/etiology , Pulmonary Embolism/diagnostic imaging , Middle Aged
2.
Ann Card Anaesth ; 27(1): 70-75, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722127

ABSTRACT: A sub-mitral left ventricular aneurysm is a rare condition. It is a congenital outpouching of the left ventricular wall, invariably occurring adjacent to the posterior mitral leaflet. Sub-mitral aneurysm (SMA) has usually been reported as a consequence of myocardial ischemia (MI), rheumatic heart disease, tuberculosis, and infective endocarditis. Nevertheless, there have been few case reports of congenital SMA in India. It usually presents with symptoms of heart failure. We report a rare case of congenital SMA in a 27-year-old young Indian and its successful management through a trans-aneurysmal approach.


Heart Aneurysm , Mitral Valve , Humans , Adult , Heart Aneurysm/surgery , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/congenital , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Male , Heart Ventricles/surgery , Heart Ventricles/diagnostic imaging , Echocardiography, Transesophageal/methods , Anesthetics
3.
Clin Cardiol ; 47(5): e24272, 2024 May.
Article En | MEDLINE | ID: mdl-38742736

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Failure , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Echocardiography, Transesophageal , Male , Treatment Outcome , Female , Aged , Reoperation
4.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article En | MEDLINE | ID: mdl-38715080

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
5.
Inn Med (Heidelb) ; 65(5): 439-446, 2024 May.
Article De | MEDLINE | ID: mdl-38597993

There is a broad spectrum of mitral valve diseases ranging from young patients with rheumatic mitral valve stenosis up to older patients with secondary mitral valve regurgitation and numerous comorbidities. A profound understanding of the etiology, anatomical characteristics of mitral valve diseases and current treatment options is necessary to be able to prepare a patient-centered treatment approach. The interdisciplinary collaboration of referring physicians, interventional cardiologists, cardiac surgeons, heart failure and imaging specialists as well as anesthesiologists is a cornerstone of optimal patient treatment.


Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/pathology , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis Implantation/methods
6.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Article En | MEDLINE | ID: mdl-38639143

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Ablation Techniques , Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Ethanol , Heart Valve Prosthesis Implantation , Mitral Valve , Humans , Retrospective Studies , Male , Ethanol/administration & dosage , Ethanol/adverse effects , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/physiopathology , Female , Treatment Outcome , Ablation Techniques/adverse effects , Ablation Techniques/mortality , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Catheterization/instrumentation , Middle Aged , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Time Factors , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Recovery of Function , Aged, 80 and over , Heart Septum/diagnostic imaging , Heart Septum/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality
8.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Article En | MEDLINE | ID: mdl-38626077

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Male , Animals , Sheep , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Chordae Tendineae/surgery , Treatment Outcome
9.
Echocardiography ; 41(4): e15813, 2024 Apr.
Article En | MEDLINE | ID: mdl-38628060

BACKGROUND: Mitral annular disjunction (MAD) is a structural abnormality characterized by the systolic detachment of the posterior mitral annulus and the ventricular myocardium. It is usually observed coexistent with mitral valve prolapse (MVP) and associated with a mechanical dysfunction despite preserved electrical isolation function of the mitral annulus. This study aimed to evaluate left ventricular (LV) function using speckle tracking echocardiography in MVP patients with MAD. METHODS: This study was designed as a prospective, single-center study including 103 patients with MVP and 40 age- and sex-matched control subjects. Transthoracic echocardiography and cardiac magnetic resonance imaging were performed to assess LV function and MAD presence. RESULTS: MAD (+) MVP (n = 34), MAD (-) MVP (n = 69), and control (n = 40) groups were enrolled in the study. Among the MVP patients, 34 (33%) had MAD. T-negativity in the inferior leads on electrocardiography was more frequent in the MAD (+) group than in the MAD (-) patients (4.3% vs. 20.6%, p = .014). Mitral regurgitation degree, Pickelhaube sign (17.6% vs. 1.4%, p = .005), and late gadolinium enhancement frequency (35.3% vs. 10.6%, p = .002) were significantly higher in MAD (+) patients. MAD (+) patients had significantly impaired global longitudinal strain (-23.1 ±  2.1 vs. -23.5 ± 2.3, p < .001), basal longitudinal strain (BLS) (-19.6 ±  1.5 vs. -20.5 ± 1.9, p < .001), Mid-Ventricular Longitudinal Strain (-22.2 ± 1.7 vs. -23.2 ± 2.2, p < .001) and LA strain (-24.5 ± 3.9 vs. -27.2 ± 3.6, p < .001) when compared to MAD (-) MVP patients, despite similar LV ejection fraction. All these values of MVP patients were also significantly lower than the control group. The mean MAD distance was 7.8 ± 3.2 mm in MAD (+) patients. Patients with two or more symptoms were higher in the MAD (+) group than in the MAD (-) group (4.3% vs. 44.1%, p < .001). CONCLUSION: This study demonstrated a significant decrease in longitudinal strain in MVP patients with MAD, indicating myocardial dysfunction. These findings suggest that MAD may contribute to LV dysfunction and highlight the importance of early detection in younger patients. Further research is needed to explore the functional implications and long-term outcomes of MAD.


Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Ventricular Function, Left , Contrast Media , Prospective Studies , Gadolinium , Mitral Valve/diagnostic imaging , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Echocardiography/methods
10.
J Nepal Health Res Counc ; 21(4): 593-598, 2024 Mar 31.
Article En | MEDLINE | ID: mdl-38616588

BACKGROUND: Rheumatic heart disease is a major cause of cardiovascular morbidity and mortality in developing nations and is a leading cause of hospital admission due to cardiac problems in our country. This study will evaluate the association between left atrial size and the occurrence of atrial fibrillation and describe the clinical characteristics along with complications related to Rheumatic Mitral valve disease. METHODS: A retrospective cross-sectional study was conducted at a tertiary care center from January 2018 to December 2019. Reports of 207 patients admitted to medical and/or surgical wards with echocardiographic diagnosis of rheumatic mitral valve disease with or without atrial fibrillation were reviewed. Data were collected, entered, and analyzed using the Statistical Package for the Social Science version 25.0. RESULTS: Among 207 patients, atrial fibrillation was present in 90 (43.5%) patients. Atrial fibrillation was higher in patients with mixed mitral valvular lesions compared to isolated mitral stenosis or mitral regurgitation. Univariate and multivariate analysis revealed left atrial size [aOR=1.067, 95% CI: 1.023 - 1.113, P= 0.002] and age [aOR = 1.073, 95% CI: 1.042 - 1.105, P<0.001] as an independent predictor of atrial fibrillation. CONCLUSIONS: Larger left atrium was an independent predictor of atrial fibrillation. Besides this, atrial fibrillation was associated with increasing age, mixed mitral valvular lesion, and moderately reduced left ventricular ejection fraction, but not associated with gender and mitral stenosis severity. Left atrial clot was significantly higher in patients with atrial fibrillation than in sinus rhythm.


Atrial Fibrillation , Mitral Valve Stenosis , Rheumatic Heart Disease , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/diagnostic imaging , Mitral Valve/diagnostic imaging , Cross-Sectional Studies , Mitral Valve Stenosis/complications , Mitral Valve Stenosis/diagnostic imaging , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Nepal , Echocardiography
11.
J Int Med Res ; 52(4): 3000605241240583, 2024 Apr.
Article En | MEDLINE | ID: mdl-38565223

Functional or secondary mitral regurgitation is linked to increased cardiovascular morbidity and mortality. From a mechanical perspective, secondary mitral regurgitation occurs due to an imbalance between the forces that tether the mitral leaflets and those that close them. This results in incomplete coaptation. Most commonly, functional mitral regurgitation, which occurs in both ischaemic and non-ischaemic disease states, is usually caused by dysfunction and changes in the left ventricle. Atrial functional mitral regurgitation (AFMR) is a disease state that has been more recently recognized. It occurs when mitral annular enlargement is associated with left atrial dilatation, preserving left ventricular geometry and function. AFMR is typically seen in patients with chronic atrial fibrillation or heart failure who have a conserved ejection fraction. Published reports and ongoing investigations vary in how they define AFMR. This publication examines the pathophysiology of AFMR and highlights the importance of having a common working standard for the definition of AFMR to ensure consistency in the data reported and to drive forward the much needed research into the outcomes and treatment strategies in this area. Several studies have reported that restrictive annuloplasty and transcatheter edge-to-edge repair can reduce mitral regurgitation and improve symptoms. This narrative review will explore the pathophysiology, echocardiographic diagnosis and treatment of AFMR.


Atrial Fibrillation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Atria/diagnostic imaging , Echocardiography , Atrial Fibrillation/complications
12.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38561823

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Retrospective Studies , Prosthesis Design , Mitral Valve Annuloplasty/adverse effects , Echocardiography , Treatment Outcome
13.
BMJ Case Rep ; 17(4)2024 Apr 29.
Article En | MEDLINE | ID: mdl-38684360

A patient in his 60s with a bioprosthetic aortic and mitral valve replacement presented with dyspnoea, tiredness and dizziness 2 years postoperatively. Transthoracic echocardiography showed mitral valve stenosis and increased pulmonary artery pressure suggesting bioprosthetic valve failure. Cardiac CT confirmed the diagnosis of bioprosthetic mitral valve thrombosis. Treatment with anticoagulation resulted in a remarkable improvement of the valve area and gradient and complete resolution of the thrombus. Herein, we report a case of rare bioprosthetic mitral valve thrombosis.


Bioprosthesis , Heart Valve Prosthesis , Mitral Valve , Thrombosis , Tomography, X-Ray Computed , Humans , Male , Bioprosthesis/adverse effects , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/drug therapy , Heart Valve Prosthesis/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Anticoagulants/therapeutic use , Echocardiography , Heart Valve Prosthesis Implantation/adverse effects , Middle Aged , Prosthesis Failure
14.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38599690

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
17.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38599692

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
19.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38576022

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Heart Valve Prosthesis , Mitral Valve , Female , Humans , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis/adverse effects , Echocardiography , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prosthesis Design
20.
Tex Heart Inst J ; 51(1)2024 Apr 26.
Article En | MEDLINE | ID: mdl-38665003

Klippel-Feil syndrome, characterized by congenital fusion of any 2 or more cervical vertebrae, is a rare disorder in which skeletal and other organ system-related abnormalities have been reported. This article reports a case of mitral valve regurgitation in a patient with Klippel-Feil syndrome and related thoracic deformity who underwent mitral valvuloplasty. Postoperatively, the mitral valve regurgitation disappeared, and there has been no recurrence for 3 years. This case highlights mitral valvuloplasty via median sternotomy as an excellent treatment for mitral valve regurgitation in a patient with thoracic deformity related to Klippel-Feil syndrome.


Klippel-Feil Syndrome , Mitral Valve Insufficiency , Humans , Klippel-Feil Syndrome/complications , Klippel-Feil Syndrome/diagnosis , Klippel-Feil Syndrome/surgery , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/diagnosis , Treatment Outcome , Sternotomy , Male , Mitral Valve/surgery , Mitral Valve/abnormalities , Mitral Valve/diagnostic imaging , Tomography, X-Ray Computed , Balloon Valvuloplasty , Female , Adult
...